Hot Line:+86-531-87165551

Impact testing machine

Description:


The working principle of the equipment is to use a high-precision photoelectric encoder and a computer with special measurement and control and calculation software to detect the difference between the potential energy before and after the impact of the pendulum to detect the impact absorbing power and the impact toughness of the material.

Display mode is double explicit: namely, dial pointer and computer display simultaneously.


Computer can display shock absorption function, impact toughness, and can make automatic test data processing, the automatic generation of test reports, take place, pin, shock, to put place such as action control can be either by hand control box of manual control, also can use a computer program by mouse input automatic control, and can batch or successive print test results.


The equipment adopts Germany Siemens PLC as the lower computer control, the brand computer as the upper computer control, and the upper computer program adopts VB programming and RS232 communication method to complete the data exchange and command transmission of the upper and lower computers, making full use of the powerful functions of PC for data processing, report processing and so on.

The rotary encoder with high precision is used to obtain the real-time position of the pendulum and obtain the shock absorption power.


It has the characteristics of system reliability, stability and data accuracy.

 

Impact testing machine Technical Parameter:


Impact energy

300J (sledge) 150 (sledge)

Impact velocity

5.2m/s

pendulum Yang Angle

150 °

Sample support span

40

Round Angle of clamp mouth of support

R1.0~1.5

Impact blade circular Angle

R2.0~2.5  R8

Distance from center of pendulum to impact point

750

Standard sample size

10 x 10(7.5 or 5) x 55

Pendulum moment

M=160.7695N.m 80.3848N.m

External dimension

about 2,100x650 x1900

he accuracy of Angle

0.1 °

Weight

about 500Kg